Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients
Oliver Gödje, Reinhard Friedl, Andreas HannekumMed Sci Monit 2001; 7(6): MT1344-1350 :: ID: 508432
Abstract
Background: Continuous determination of cardiac output (CO) by transpulmonary thermodilution calibrated pulse-contour analysis is gaining clinicical acceptance. However there is doubt, whether this method is reliable in hemodynamic instable patients. We compared pulse-contour analysis to thermodilution in patients with profound changes of CO.
Material and methods: 24 patients were investigated. CO was measured by thransthoracic thermodilution and pulse-contour analysis in intervals of 60 min during study periods of 8–44 h without recalibration of the pulse-contour computer. Results of 517 measurements were compared by regression, structural regression and Bland-Altman analyses.
Results: Mean change of CO was 40±27% (range 20–139%), range of systemic vascular resistance was 450 dyn·s/cm–5 – 2360 dyn·s/cm–5. Correlation of pulse-contour analysis CO to thermodilution CO was r=0.88 with p=0.0001, bias was 0.2 l/min with 1.2 l/min standard deviation. Mean CO by pulse-contour analysis did not differ significantly from CO by thermodilution during the study period. There were no influences of heart rate or arterial pressure on the difference between both methods.
Conclusion: CO measurement by arterial pulse-contour analysis is reliable even in patients with profound changes of CO or during hemodynamic instability.
Keywords: Cardiac Output, pulse-contour analysis, Thermodilution, Intensive Care
Editorial
01 March 2024 : Editorial
Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-ThalassemiaDOI: 10.12659/MSM.944204
Med Sci Monit 2024; 30:e944204
In Press
21 Feb 2024 : Clinical Research
Potential Value of HSP90α in Prognosis of Triple-Negative Breast CancerMed Sci Monit In Press; DOI: 10.12659/MSM.943049
22 Feb 2024 : Review article
Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...Med Sci Monit In Press; DOI: 10.12659/MSM.943168
23 Feb 2024 : Clinical Research
A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...Med Sci Monit In Press; DOI: 10.12659/MSM.943732
26 Feb 2024 : Clinical Research
Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...Med Sci Monit In Press; DOI: 10.12659/MSM.942509
Most Viewed Current Articles
17 Jan 2024 : Review article
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
16 May 2023 : Clinical Research
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
14 Dec 2022 : Clinical Research
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
01 Jan 2022 : Editorial
Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...DOI :10.12659/MSM.935952
Med Sci Monit 2022; 28:e935952